5.4 Detailed OSEIS Decoder Operation
5.4.1 Uphole Geophone Resistance Test
Press Test button on Front Panel to test Uphole Geophone
Boom Box 3 Compares reading with internal limits
Geophone Test includes
o Resistance measures DC resistance
o Frequency geophone must be planted in vertical position for frequency to pass
o Damping - geophone must be planted in vertical position for damping to pass
o Sensitivity -geophone must be planted in vertical position for sensitivity to pass
Flashes Test LED green 4 times if result is within entered limits and there is a sensitivity
reading.
Flashes Test LED red 4 times if result is outside entered limits or there isn’t a sensitivity
reading.
Geophone resistance will be shown on the Armed and Ready display.
5.4.2 OSEIS CAP Test
Press Test button and ARM switch on Front Panel to test CAP
Flashes Test LED green 2 times if result is within entered limits
Flashes Test LED red 2 times if result is outside entered limits
CAP results will be shown on the display.
5.4.3 GPS
Press GPS button to acquire new GPS position 10 seconds.
GPS LED is RED for the first 4 seconds to show the GPS button was pressed.
Solid green GPS LED with a differential position.
Flashing green GPS LED with a non-differential position.
Solid red GPS LED when a bad position was received.
No GPS LED when no GPS information is received within 10 seconds of pressing the GPS
button.
The GPS LED’s will stay this way until pressing the GPS button again or taking the next
shot.
5.4.4 Fire Sequence OSEIS Decoder
Press both the Arm and Charge switch to Arm the Boom Box and the OSEIS blasting cap.
Arming the OSEIS blasting cap takes between 4 to 6 seconds.
If the Ready Message is enabled the Ready Message will be automatically sent when the
high voltage capacitor is fully charged, and box is ready to fire.
When valid Start Code is received from the Encoder unit, the shot sequence is started, and
the fire message is sent to the Cap line and the Shot is fired.
Test LED will flash green for 4 seconds after shot for Confirmed Time Break is OK
GPS LED will flash green after shot if first break is detected on Uphole geophone
GPS LED will flash red after shot if first break is not detected
The display will show Uphole time, CTB value, and Battery voltage.