47 BOOM BOX 3 Dynamite Controller
13 ISO_SPARE_IN_RET Isolated Spare IN Return.
14 ISO_TB_ACT Isolated output. Isolated Time Break Active. Used in
Encoder and Decoder modes. Isolated with 4N32 opto coupler. Polarity
selected by software menu in Encoder Mode. Polarity is always active low in
Decoder mode.
15 ISO_TB_RET Isolated Time Break Return.
16 NISO_TB_A Non-isolated Time Break. Used in Encoder and Decoder
modes. Polarity selected by software menu in Encoder Mode. Polarity is
always active low in Decoder mode. +3.3 volts to 0 volts.
17 ISO_RECSTART_ACT Isolated output. Isolated Recorder Start Active.
Pre-Start pulse in Encoder, Master, Repeater, and Slave modes. Isolated with
4N32 opto coupler. Polarity selected by software menu.
18 ISO_RECSTART_RET Isolated Recorder Start Return.
19 BAT + - Not connected on Version 2 cards - Jumper J12 on board if needed.
20 BAT - - Battery Ground.
21 UPHOLE + - Input. Uphole Geophone connection. 1.566 volts to +1.526
volts.
22 UPHOLE - - Input. Uphole Geophone connection.
23 +5VD Output. +5 volts digital.
25 SPKR_ACT Input. Speaker Active to Boom Box 3 from external radio
speaker output.
26 SPKR_RET Speaker return. Speaker return from external radio speaker
return.
27 PTT_ACT Output. Push to Talk Active from Boom Box 3 to external radio.
28 RADIO_RET Radio return. Radio return from external radio ground
29 MIC_ACT Output. Microphone Active from Boom Box 3 to external radio
microphone input.
30 RADIO_UPHOLE AUX 1 output. Encoder, Master, and Repeater produce
the Uphole signal after the decoder fires the shot and returns the post report. -
1.65 volts to +1.65 volts.
31 TTL_OUT 1 Not currently used.
32 TTL_OUT 2 - Not currently used.
33 ISO_REF_PULSES_ACT AUX 2 isolated output. Reference pulses
Active. Occurs in Encoder, Master, and Repeater modes after the Fire
sequence. Uses a 4N32 opto-coupler.
34 ISO_REF-PULSES_RET Reference pulses Return.
35 NISO_REF_PULSES AUX 2 non-isolated output. Reference pulses.
Occurs in Encoder, Master, and Repeater modes after the Fire sequence. 0 to
+3.3 volts.
36 NISO_RECSTART Non-isolated output. Recorder Start Active. Pre-Start
pulse in Encoder, Master, Repeater, and Slave modes. Polarity selected by
software menu. +3.3 volts to 0 volts.
37 Not connected on Version 1.03 boards -BAT + - - Battery positive DC
power input on Boom Box 3 (10-37 volts DC). Jumper J11 on board if
needed.
GPS Connections:
External GPS with external corrections.
4 GPS A RX Not used.