83 BOOM BOX 3 Dynamite Controller
14.2.2.3 Operating mode: Standard Decoder
Boom Box 3 Parameters section describe these entries.
Cap Type: This entry selects what type of detonator to fire.
Standard is the electric detonator and use the high voltage. The front panel hardware
switch must be on Standard.
OSEIS uses the internal Orica board (if installed) and fires the OSEIS detonators. The
front panel hardware switch must be on OSEIS.
Austin uses the external E-Star blaster for Austin detonators. The front panel hardware
switch must be on Standard.
Dyno uses the internal DYNO board (if installed) and fires the Dyno electronic detonators.
The front panel hardware switch must be on OSEIS.
Maxam Int. uses the internal MAXAM board (if installed) and fires the MAXAM
electronic detonators. The front panel hardware switch must be on OSEIS. (Source
Control F3 v.3.26 or newer must be used for this entry)