Appendix B Error and Event List
Error
Description
12V Supply Error
Voltage on 12V rail has exceeded safe operational range.
3.3V Supply Error
Voltage on 3.3V rail has exceeded safe operational range.
5V Supply Error
Voltage on 5V rail has exceeded safe operational range.
AFD Not Present
Auto Conversion is enabled in Video Service configuration but
the stream does not contain an AFD code.
ANC/VBI Line Conflict -
AFD
The VANC line AFD is currently set to be embedded on is
conflicting with another line of data in the VANC.
ANC/VBI Line Conflict -
AMOL
The VANC line AMOL is currently set to be embedded on is
conflicting with another line of data in the VANC.
ANC/VBI Line Conflict -
CC
The VANC line CC is currently set to be embedded on is
conflicting with another line of data in the VANC.
ANC/VBI Line Conflict
EN301775
The VANC line EN301775 is currently set to be embedded on is
conflicting with another line of data in the VANC.
ANC/VBI Line Conflict
OP47
The VANC line OP47 is currently set to be embedded on is
conflicting with another line of data in the VANC.
ANC/VBI Line Conflict
RDD11
The VANC line RDD11 is currently set to be embedded on is
conflicting with another line of data in the VANC.
ANC/VBI Line Conflict
SCTE127
The VANC line SCTE127 is currently set to be embedded on is
conflicting with another line of data in the VANC.
ANC/VBI Line Conflict
SMPTE2038
The VANC line SMPTE2038 is currently set to be embedded on
is conflicting with another line of data in the VANC.
ANC/VBI Line Conflict
Source ID
The VANC line Source ID is currently set to be embedded on is
conflicting with another line of data in the VANC.
ANC/VBI Line Conflict
System Timecode
The VANC line Timecode is currently set to be embedded on is
conflicting with another line of data in the VANC.
ANC/VBI Line Conflict -
Teletext
The VANC line Teletext is currently set to be embedded on is
conflicting with another line of data in the VANC.
ANC/VBI Line Conflict
TVG2X
The VANC line TVG2X is currently set to be embedded on is
conflicting with another line of data in the VANC.
ANC/VBI Line Conflict -
VII
The VANC line VII is currently set to be embedded on is
conflicting with another line of data in the VANC.
ANC/VBI Line Conflict -
VPS
The VANC line VPS is currently set to be embedded on is
conflicting with another line of data in the VANC.
ANC/VBI Line Conflict -
WSS
The VANC line WSS is currently set to be embedded on is
conflicting with another line of data in the VANC.
Audio Not Decoding
Audio is corrupted in incoming stream or format is not supported.
Auto Video Format Error
MRD 5800 is unable to determine the native incoming video in
order to format output.
BISS Conflicting PIDs
PIDs selected to be descrambled by one BISS key are already