5
Mechanical installation
Assembly
Operating Instructions – MOVIPRO
®
PHC11A-..M1-..2A-A1/..
39
36028797493776523
[1] Mounting elements, e.g. M6 screws
[2] Locking elements, e.g. lock washers
[3] Mounting elements, e.g. washers
[4] Mounting surface, e.g. mounting plate
X, Y Housing dimensions
X
2
, Y
2
Bore dimensions
Procedure
1. Refer to the dimension drawing in chapter “Technical data” for the housing dimen-
sions X and Y.
2. Refer to the following table for dimensions of the bores:
Bore di-
mension
Value
X
2
Housing dimension X − 30 mm (1.2 in), see the following dimension
drawing
Y
2
Housing dimension Y − 30 mm (1.2 in), see the following dimension
drawing
3. Mark the tapped holes on the mounting surface [4].
4. Drill the bores at the marked points.
5. Firmly screw the unit on the mounting surface [4] from the front via the through
bores. Use suitable mounting and locking elements, e.g.:
• M6 screws [1]
• Lock washers [2]
• Washers [3]
Fastening the unit from the back
Required material:
• Observe the required minimum distances and clearances by using one of the fol-
lowing mounting elements:
20278543/EN – 09/2014