MX-M700N FAN AND FILTER SECTION R – 5
3) Disconnect the connector, and remove the process cooling fan
unit.
4) Disconnect the connector, and remove the process cooling fan
motors 1 (A), 2 (B), and 3 (C).
* When assembling, fit the mark with the fan rotating direction.
(label on the back surface)
B. Filters
(1) Ozone filter
1) Remove the rear cabinet.
2) Release the pawl, and remove the ozone filter.
A
B
C
Fan blowing direction
RE
VERS
E
Marks
Mark
No. Parts
(1) Ozone filter
(2) DV ozone filter
(3) Toner filter
(1)
(2)
(3)