17(107)
The feeding blower has great suction power and it is easy to get goods or
clothes sucked into, which will cause personal injury!
For SG-30, the cutting chamber should be heat-processed and the
blades must be changed before the granulator deal with fibre added
material.
Attention!
No need of regular inspection because all the electrical parts in the
electric components box are fixed tight!
Warning!
When this light is on, it means overload working and growing flow.
Please stop feeding until the light is off.
Attention!
1. After the first 1-2 days of operating, it’s necessary to loose the four
screws on motor fixing base and then tighten this screw up for
tightening belt.
2. Whenever belt slip occurs, please tighten up this screw.
Air inlet
Clean dust.
Please add butter lubricant regularly.
When operate the granulator, please notice the following signs: