Operation (Specialist Menus)
GM32
·
Technical information
·
8011923
·
V
1.4
·
©
SICK AG
55
Subject
to ch
ange wi
thout
notic
e
Normalisation
Menu: GM32/Diagnosis/Sensor values/Spectra/Normalisation
Graphic repr
esentation of normalisat
ion (constants for zero adjust).
Normalisation must
be between 0.8 and 5.
54
56
Table of Contents
Default Chapter
4
Table of Contents
4
1 General Information
7
Responsibility of User
8
Designated Users
8
Special Local Conditions
8
2 Product Description (Details)
9
Measuring Method
10
Optics Layout and Functional Principle
10
Signal Evaluation
11
Zero Adjust (Description)
12
Reference Cycle (Description)
12
Reference Cycle Sequence
12
Check Cycle (Description)
12
Control Elements
12
Check Cycle (Function)
13
Wavelength Scale Monitoring
13
Resolution Drift Monitoring
13
Absorption Drift Monitoring
13
Determining the Zero and Reference Point
14
Monitoring the Cell no Filling
14
Summary
15
Events and Signals Output
15
Check Cycle Signals
15
Maintenance Request Signal
15
Zero and Reference Point Level Output
15
Contamination Compensation
16
Monitoring Contamination
16
Automatic Adjustment with Alignment
16
Measuring Probe in Detail
17
3 CAN Connection
21
GM32 CAN Connection
22
SCU Connection (Overview)
23
Connecting the GM32 to the CAN Bus and to the SCU
24
Settings in GM32
25
Settings in the SCU
25
Mapping Table
26
4 Operation (Specialist Menus)
29
SOPAS ET (Description)
30
Menu Tree (in SOPAS ET)
31
Changing the User Level
32
Measured Values
33
Bargraph Measured Values
33
Parameters
34
Device Parameters
34
Spectrometer
35
Coefficients
35
Coefficients Boxmeasuring
36
Adjustment Sensor
36
Logbook
37
Analog Outputs
38
Analog Inputs
38
Digital Inputs
39
Digital Outputs
39
Hardware Map
41
Adjustment
42
Alignment
42
Zero Adjust (Service Level Only)
43
Boxmeasuring (Service Level Only)
44
Diagnosis
45
Device Information
45
Logbook
45
Check Cycle
47
Sensor Values
47
Temperature Unit
50
Spectra
51
Maintenance
56
Operating Mode Switch
56
Lamp Hour Meter
56
Save EEPROM
57
Load EEPROM
57
Start-Up Assistant
57
Program/Data Structure ("Firmware", "Device Description File")
58
Sequence of Settings and File Transfers
58
Setting the GM32 Analyzer/Scu IP Address
59
Updating the Firmware (GM32 Analyzer/Scu)
60
Loading the Device Description File ("Make Available to SOPAS ET")
61
Saving and Loading Parameters (Device Data)
62
Loading Parameters Changed in SOPAS ET to the GM32 Analyzer/Scu
62
Saving Parameters (GM32 Analyzer/Scu) to an External Data Medium
63
Loading Parameters from an External Data Medium to the GM32 Analyzer
63
Scu
63
Loading Data Files from the Device
63
5 Maintenance
65
Zero Adjust (Zero Point Check)
66
Procedure
66
Boxmeasuring
68
Preparing the Filter Box
69
Determining the Necessary Test Gas Concentration
71
Procedure
72
Test Gas Feeding (for GPP Measuring Probe)
76
One-Off Initial Measurement - Determining the Test Gas Pressure
77
Manual Test Gas Feeding
78
Using Mixed Gases as Test Gases
78
Fitting and Removing the Power Supply Unit of the Connection Unit
79
6 Shutting Down/Restarting
81
Qualification Requirements
82
Shutting down
82
Equipment Required
82
Shutdown
83
Removing from the Sample Gas Duct
83
Disconnecting the Purge Air Connection
84
Putting the Purge Air Unit out of Operation
85
Further Components on the Measuring Point
86
Connection Unit and Cabling
86
Conservation Measures, Correct Storage and Transport
87
Preparing for Restarting
89
New Measuring Task
89
Previous Measuring Task
89
Purge Air Unit Maintenance
89
7 Annex
91
Commissioning Checklist
92
Other manuals for SICK GM32
Operating Instructions
80 pages
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the SICK GM32 and is the answer not in the manual?
Ask a question
SICK GM32 Specifications
General
Brand
SICK
Model
GM32
Category
Measuring Instruments
Language
English
Related product manuals
SICK DL100
144 pages
SICK VMS6200
84 pages
SICK DL100 Pro
126 pages
SICK MLG-2 Pro
138 pages
SICK FLOWSIC500
176 pages
SICK DUSTHUNTER T
552 pages
SICK S100 Standard
72 pages
SICK FLOWSIC600-XT
164 pages
SICK LMS500 Series
98 pages
SICK DUSTHUNTER T50
261 pages
SICK DUSTHUNTER T100
261 pages
SICK MLG-2 WebChecker
132 pages