Display Possible cause Troubleshooting
Ö
Red ERR
o
Blue 1
Ö
Blue 2
o
Blue 3
o
Blue 4
o
Blue 5
Short-circuit,
cr
oss-circuit or
cable defect
b
Chec
k the function of the reset button. The
pushbutton may be defective or being pressed
continuously.
b
Check the wiring for short-circuit to 24 V or
0 V.
b
Check the wiring between host and guest or
between host, guest and guest.
b
Check the wiring between the two OSSDs.
Ö
Red ERR
o
Blue 1
o
Blue 2
Ö
Blue 3
o
Blue 4
o
Blue 5
Supply voltage
t
oo low
b
Chec
k the supply voltage and the power sup‐
ply unit. Replace defective components if nec‐
essary.
Ö
Red ERR
o
Blue 1
o
Blue 2
o
Blue 3
Ö
Blue 4
o
Blue 5
Fault due to
ambient li
ght
b
Chec
k the distance to reflective surfaces or to
other safety light curtains. If necessary,
mount non-reflective partitions.
Ö
Red ERR
o
Blue 1
o
Blue 2
o
Blue 3
o
Blue 4
Ö
Blue 5
System error
b
Switch the voltage supply of the miniTwin4 off
and back on (renewed power-up).
b
If the display also lights up during repeated
power-up during the start-up phase, replace
the device.
b
If the display lights up during operation, con‐
tact SICK support.
Ö
White COM Fault during com‐
munic
ation
between 2 twin
sticks
b
Chec
k the alignment of the two twin sticks
with one another.
Or, if a twin stick has been replaced:
b
Switch the voltage supply for both twin sticks
off and then back on again.
Ö
Red ERR
Ö
Orange EDM
EDM errors
b
Chec
k the contactors and their wiring, fix the
wiring error if necessary.
Ö
Red ERR
Ö
Orange EDM
Ö
Orange RES
Error during con‐
f
iguration of EDM
or reset or
cabling of Pin 2
b
R
epeat configuration of EDM or reset.
Or:
b
Check the cabling Pin 2.
Ö
Orange EDM
Ö
Orange RES
Configuration of
EDM or r
eset not
yet performed.
b
S
witch on the connected relay or the contac‐
tor.
Or:
b
Actuate the connected reset button.
Or:
b
Check the cabling Pin 2.
Further topics
"St
atus indicators", page 17
"Minimum distance from reflective surfaces", page 25
"Minimum distance for cascaded systems", page 26
"Configuring reset", page 64
"Protective operation without reset and/or without EDM", page 31
TROUBLESHOOTING 11
8012624/10OM/2018-08-09 | SICK O P E R A T I N G I N S T R U C T I O N S | miniTwin4
87
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK miniTwin4 and is the answer not in the manual?

SICK miniTwin4 Specifications

General IconGeneral
BrandSICK
ModelminiTwin4
CategorySecurity Sensors
LanguageEnglish

Related product manuals