13 Technical data
13.1 Data sheet
General system data
T
able 17: General system data
Minimum Typical Maximum
Protective field height, depending on
t
ype
120 mm to 1,200 mm
Resolution (detection capability),
dependin
g on type
14, 24 or 34 mm
Scanning range
1)
2)
0-4.0 m 0-5.0 m
With 1 additional front screen 0-3.7 m 0-4.6 m
With 2 additional front screens 0-3.4 m 0-4.2 m
With 1 deflector mirror
3)
0-3.6 m 0-4.5 m
With 2 deflector mirrors
3)
0-3.2 m 0-4.0 m
Protection class
4)
III (IEC 61140)
Enclosure rating IP65 (IEC 60529)
Supply voltage U
V
a
t the device
5)
19.2 V 24 V 28.8 V
Residual ripple
6)
±10%
Type Type 4 (IEC 61496-1)
Category Category 4 (ISO 13849-1)
Performance level
7)
PL e (ISO 13849–1)
N
ote the optical performance characteristics!
8)
Safety integrity level
7)
SIL3 (IEC 61508)
SIL claim limit
7)
SILCL3 (IEC 62061)
PFHd (mean probability of a dangerous failure per hour)
Single system 4.3 x 10
–9
Cascaded systems 13 x 10
–9
T
M
(mis
sion time) 20 years (ISO 13849-1)
Safe status when a fault occurs At least one OSSD is in the OFF state.
Power-up delay after supply voltage
applied
3 s
Wavelength 850 nm
Output signal switching devices
(O
SSDs)
PNP semiconductor, short-circuit protected
9)
, cross-cir‐
cuit monitored
Switching voltage
10)
11)
HIGH (active,
U
eff
)
U
v
- 2.2 V 24 V U
v
Switching voltage LOW (deactivated) 0 V 0 V 2 V
Switching current 0 mA 300 mA
Single system leakage current
12)
0.25 mA
Cascaded system leakage current
12)
0.5 mA
Load capacity 1 µF
Switching sequence Depending on the load inductance
Load inductance
13)
2.2 H
Test pulse data
14)
TECHNICAL DATA 13
8012624/10OM/2018-08-09 | SICK O P E R A T I N G I N S T R U C T I O N S | miniTwin4
89
Subject to change without notice