Minimum Typical Maximum
Response time of single device with
24 or 34 mm r
esolution
13 ms
Additional response time for cas‐
caded systems (host/guest)
2 ms
Additional response time for cas‐
caded systems (host/guest/guest)
4 ms
Power-down time
1)
80 ms
Power-up delay 200 ms
1)
According to IEC 61496-2.
13.3 Power consumption
Table 21: Power consumption
Protective field height in mm Maximum power consumption in W
1)
120 2.5
180 2.5
240 2.5
300 3.1
360 3.1
420 3.7
480 3.7
540 4.3
600 4.3
660 4.9
720 4.9
780 5.5
840 5.5
900 6.1
960 6.1
1020 6.7
1080 6.7
1140 7.3
1200 7.3
1)
Power discharged again via the OSSDs depending on the connected OSSD load must be added to the
t
able values.
13.4 Table of weights
miniTwin4
T
able 22: Weight miniTwin4
Protective field height in mm Weight in g
120 50
180 75
240 95
300 115
360 135