8 IPG protective pipes
In cases where an MLG-1 is installed in an IPG protective pipe, you must also order a
new IPG protective pipe when switching over to the MLG-2. For details of how to mount
IPG protective pipes, see the “IPG2 protective pipe for MLG-2 light grid” mounting
instructions (part number 8018943). The distance between the lower edge of the IPG
protective pipe housing and the first beam is not the same on the MLG-2 as on the
MLG-1. Even if the detection height is kept exactly the same, the total length of the IPG
protective pipe has to be longer for the MLG-2 than for the MLG-1.
b
Remember to take account of this difference during planning and mounting.
IPG for MLG-1
15 (0.59)
8
(0.31)
35
(1.38)
8.5
(0.33)
Ø 52
(2.05)
Ø 6 (0.24)
L
L + 69 (2.72)
6
(0.24)
L + 102 (4.02)
15 (0.59)
Ø 50
(1.97)
6
(0.24)
35
(1.38)
60.5
(2.38)
Figure 29: MLG-1 with IPG protective pipe
L Protective pipe
8 IPG PROTECTIVE PIPES
36
T E C H N I C A L I N F O R M A T I O N | The MLG-2 as a replacement product for the MLG-1 and XLG 8020351.ZLW3/2017-05-03 | SICK