5 Mounting
5.1 Mounting instructions
Observe the technical data.
Protect the sensor from direct sunlight.
To prevent condensation, avoid exposing the device to rapid changes in tempera‐
ture.
The mounting site has to be designed for the weight of the device.
To avoid inaccurate measurements when installing multiple devices: Make sure
that the light spot of one device is not in the interference range of another device.
5.2 Mounting the device
Approach
1. Mount the device using the designated fixing holes. Note the permissible tighten‐
ing torque of the screws (max.0.8Nm).
2. Make the electrical connection. Attach and tighten a voltage-free cable.
3. Switch on the supply voltage.
The PWR status LED lights up green.
4. Align the light spot so that the device measures on the desired object.
Further topics
Dimensional drawing
Connecting the device electrically
MOUNTING 5