9 Troubleshooting
9.1 Faults
The following table describes possible faults and troubleshooting measures. In the case
of faults that cannot be rectified using the information below, please contact SICK
Service. To find your agency, see the final page of this document.
NOTE
Before calling, make a note of all type label data such as type code, serial number, etc.,
to ensure faster processing.
General faults are subdivided into warnings and errors. Current measured values con‐
tinue being output when there are warnings; measurement is no longer possible when
there are faults.
Table 9: Troubleshooting questions and replies
Question/status Response/remedial actions
The device does not display a meas‐
urement or measurement is not pos‐
sible.
Sender not activated: Switch on sender, see "Sender
menu", page 46.
Laser light spot is not aimed at object: Check align‐
ment of the device and correct if necessary.
Make sure that the light path is clear.
Ensure that the object is within the measuring range.
Ensure that the receiver element of the device is
receiving enough light.
Reflective surfaces: Check surface condition.
EMC disturbed environment Recommendation: Use data output via IO-Link.
If measured values must be output via the analog out‐
put, use an analog current output. The analog current
output is significantly less susceptible to electromag‐
netic interference than a voltage output.
9.2 Information for service cases
You should collect and write down the following device information ahead of time if you
need to contact SICK Service:
Information about the firmware version
Information about the hardware
Information about operating hours
This information can be called up via the display.
9.3 Returns
Only send in devices after consulting with SICK Service.
The device must be sent in the original packaging or an equivalent padded pack‐
aging.
NOTE
To enable efficient processing and allow us to determine the cause quickly, please
include the following when making a return:
Details of the contact person
Description of the application
Description of the fault that occurred
TROUBLESHOOTING 9
8026231/1I18/2023-01-05 | SICK O P E R A T I N G I N S T R U C T I O N S | OD2000
49
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK OD2000 and is the answer not in the manual?

SICK OD2000 Specifications

General IconGeneral
BrandSICK
ModelOD2000
CategoryAccessories
LanguageEnglish

Related product manuals