Display Possible cause Remedy

Short-circuit on control
in
puts A1/2 or incorrect
operation of A1/2 via
EFI
b
Chec
k the wiring, the digital control inputs or
the wiring to the devices connected via EFI.

Short-circuit on control
in
puts B1/2 or incorrect
operation of B1/2 via
EFI

Short-circuit on control
inputs C1/2 or incorrect
operation of C1/2 via
EFI

Short-circuit on control
inputs D1/2 or incorrect
operation of D1/2 via
EFI

Incorrect operation of
E1/2 v
ia EFI
Park/standby mode,
the OSSDs are in the
OFF state; the laser is
switched off.
Not an error. Operational readiness is restored by
switching to a different monitoring case or with‐
drawing the standby bit via EFI.
A device connected via
E
FI reports a malfunc‐
tion.
b
C
arry out a fault diagnosis of the device con‐
nected to the affected device.
Front screen calibration
ac
tive
Not an error
...
Channel 1 to 6 of the
cont
amination measure‐
ment contaminated
b
Cle
an the front screen.

No front screen fitted or
d
azzling of the contami‐
nation measurement
b
F
it the new front screen (then carry out a front
screen calibration).
If a front screen was fitted at the time of the error:
b
Check whether the device is being dazzled by
an external light source, e.g., headlight,
infrared light source, stroboscopic light, sun
etc.

and

Traceability data incor‐
r
ect or front screen cali‐
bration failed
b
C
arry out a front screen calibration or replace
the device if necessary.

Device internal error
b
R
eplace the device.

I/O module internal
er
ror
b
R
eplace the device.
1)
If the contour as reference function is configured.
Further topics
"S
tatus indicators", page 16
"Pin assignment", page 61
"Park/standby mode", page 89
10 T
ROUBLESHOOTING
104
O P E R A T I N G I N S T R U C T I O N S | S3000 Cold Store 8012029/ZA20/2019-11-14 | SICK