Display Possible cause Remedy
Device is addressed as
hos
t
Not an error. The symbol is displayed for approx.
2 seconds when a device that is addressed as a
host is switched on.

The device is receiving
no measured values
within a range of at least
90° (maximum measur‐
ing range of 49 m) and
is therefore not detect‐
ing any obstacles
present there, for exam‐
ple building walls.
b
F
or correct functioning of the safety laser
scanner, always ensure that measured values
are received within a range of 90°; this range
can be moved as required within the scan
range.

Device is dazzled
b
Check whether the device is being dazzled by
an external light source, e.g., headlight,
infrared light sources, stroboscopic light, sun
etc.
b
If necessary, re-mount the device.

Temperature error. The
oper
ating temperature
of the device is outside
the permitted range.
b
Chec
k whether the device is being operated as
per the permissible ambient conditions.

Invalid configuration of
t
he EDM
b
Chec
k that the machine-side EDM is con‐
nected correctly.

The addresses of both
t
he host device and the
guest device may have
been set to guest.
A device connected via
EFI or the connection to
the device is defective
or disrupted.
b
R
emove the jumper on the host device.
b
Check the connected device and the connec‐
tion to this device.

There is a short-circuit
be
tween the reset input
and another input or
output, or the reset
pulse does not fulfill the
requirements.
b
Chec
k the wiring for cross-circuits.
Or:
b
Check whether the reset pulse fulfills the
requirements (see figure 61).

Input signal for a non-
de
fined monitoring case
b
Chec
k the path of the vehicle.
Or:
b
Check the operating process of the monitored
machine or system.
b
If necessary, check the configuration of the
monitoring cases using the CDS.

Incorrect sequence
when s
witching the mon‐
itoring cases

Incorrect operation of
the control inputs
b
Chec
k the operation of the digital control
inputs.
TROUBLESHOOTING 10