MAINTENANCE AND REPAIR 7
103
Subject to change without notice
ORIGINAL OPERATING INSTRUCTIONS| VMS4200/5200 (Multicontroller)
Fig. 82: Dowel pins and locating holes
Press the device into place with one hand and screw the device to the mounting plate.
Make sure that the device is securely screwed on.
Screw the connecting cables back on.
Switch the voltage supply back on.
Check that the status LED lights up green after approximately 40 seconds.
Conduct a test run and check whether the multi-dimensional measurement system
is providing plausible measurement results.
NOTE! It may be necessary to recalibrate the exchanged 2D LiDAR sensor using SOPAS.
After replacing a component, contact the manufacturer.
The manufacturer will arrange for the system to be reverified after the replacement of
a component.
Mounting the
replacement device
Test run
Restoring
MID conformity