6 COMMISSIONING
8022965-17I6/2020-03-19|SICK
ORIGINAL OPERATING INSTRUCTIONS| VMS4200/5200 (Multicontroller)
Subject to change without notice
6.2.3 Assigning IP addresses
IP addresses in the delivery state:
Component Default IP address
SIM2000 system controller 192.168.0.1
SIM2000 dimensioning controller
VMS4200/5200 (Multicontroller) only
192.168.0.1
LMS4x21 master 192.168.0.1
LMS4x21 slave 192.168.0.1
Tab. 19: Default IP addresses of device components
Recommended CAN and IP address assignments:
Component CAN TCP/IP
SIM2000 system controller 32 192.168.0.32
SIM2000 dimensioning controller
VMS4200/5200 (Multicontroller) only
31 192.168.0.31
LMS4x21 master 25 192.168.0.25
LMS4x21 slave 26 192.168.0.26
Tab. 20: Recommended addresses of device components
As the IP addresses are the same, the IP addresses must be assigned for each device
individually.
Fig. 75: Procedure for assigning IP addresses
▸
Make sure that the 2D LiDAR sensors are mounted correctly and electrically connected.
▸
Detach all Ethernet connections from the Ethernet switch so that only one 2D LiDAR
sensor is connected to the Ethernet switch.
▸
Connect the configuration PC to a free port on the Ethernet switch
▸
Make sure that the configuration PC is in the number range of the connected device
components.
If it is not, change the IP address of the configuration PC accordingly.
Overview
Procedure