ELECTRICAL INSTALLATION 5
81
Subject to change without notice
ORIGINAL OPERATING INSTRUCTIONS| VMS4200/5200 (Multicontroller)
5.8 Connection for the photoelectric retro-reflective sensor (optional)
For the VMS4200/5200 and VMS4200/5200 (Multicontroller) system variants,
the (optional) photoelectric retro-reflective sensor is connected in the same manner
to the system controller.
Fig. 72: Connection for the trigger photoelectric retro-reflective sensor (optional)
Trigger signal
Wire color Terminal Connection
Black X4 INPUT A 1 IN1+
Brown X4 INPUT A 7 24 V
Blue X4 INPUT A 8 GND ISO (X4)
Tab. 18: Connection for the photoelectric retro-reflective sensor trigger (optional)
If the trigger signal comes from an external source, the switching input can be
connected to the controller in a volt-free manner.
In this case, the DIP switch S1 must be set to GND_ISO (X4).
The connection with terminal 7 (24 V) can be omitted.
External
trigger signal