3 SYSTEM DESCRIPTION
8022965-17I6/2020-03-19|SICK
ORIGINAL OPERATING INSTRUCTIONS| VMS4200/5200 (Multicontroller)
Subject to change without notice
3.6.2 Security seal
In order to protect measurement systems that have been verified as legal for trade
against manipulation, all legally relevant components that influence the measurement
result must be provided with seals in accordance with the seal diagram depicted in the
figure below.
The security seals are attached to the VMS5200 (Multicontroller) components after
mounting and the conformity assessment.
NOTE! Never break any seals. A broken seal causes the legal for trade calibration period
to end ahead of schedule. The VMS5200 (Multicontroller) is then no longer permitted to
be used for billing purposes.
▸
The incident must be reported to the manufacturer and the office of weights and
measures.
Security seals prevent the attachment mechanism of the 2D LiDAR sensors and the plug
connectors of the connections from misaligning.
Fig. 28: Security seal on the 2D LiDAR sensors of the VMS5200 (Multicontroller)
Legend
1 Security seal on the mounting plate of the modular bracket on the frame
2 Security seal on the two adjusters of the telescopic tube
3 Security seal on the mounting plates of the 2D LiDAR sensors
4 Security seal on all plug connectors for the electrical connections
Seal on the
2D LiDAR sensor