3 SYSTEM DESCRIPTION
30
8022965-17I6/2020-03-19|SICK
ORIGINAL OPERATING INSTRUCTIONS| VMS4200/5200 (Multicontroller)
Subject to change without notice
3.5 Nominal operating conditions
The VMS4200/5200 multi-dimensional measurement system (Multicontroller) can
determine the length, width, and height of the smallest rectangular box that fully encloses
cubic and irregularly shaped measuring objects. The VMS5200 (Multicontroller) is
certified to the Measuring Instruments Directive specified in chapter 9.3 Compliance with
EU directives.
The different nominal operating conditions according to the different nominal operating
conditions depending on the object size are described below.
3.5.1 Fixed scale values
If the plant is operated without scale value switchover, the measuring range and the
scale interval value are fixed throughout the entire system depending on the application,
and are therefore the same for all measured objects.
Measuring range and scale interval value for VMS5200 (Multicontroller) - Operating condition 1
Min.
Max.
Scale value (d)
Remarks
Length
50 mm
2.0"
5,500 mm
216.0"
5 mm
0.2"
Longest dimension of the measuring
object
Width
50 mm
2.0"
1,600 mm
63.0"
5 mm
0.2"
Dimension of the measuring object
orthogonal to the longest dimension
Height
20 mm
1.0"
1,100 mm
43.0"
2 mm
0.1"
Maximum height of the measuring
object relative to the transport belt
surface
Tab. 1: Measuring range and scale interval value for VMS5200 (Multicontroller) - Operating
condition 1
Measuring range and scale interval value for VMS5200 (Multicontroller) - Operating condition 2
Min.
Max.
Scale value (d)
Remarks
Length
50 mm
2.0"
5,500 mm
216.0"
5 mm
0.2"
Longest dimension of the measuring
object
Width
50 mm
2.0"
1,600 mm
63.0"
5 mm
0.2"
Dimension of the measuring object
orthogonal to the longest dimension
Height
50 mm
2.0"
1,100 mm
43.0"
5 mm
0.2"
Maximum height of the measuring
object relative to the transport belt
surface
Tab. 2: Measuring range and scale interval value for VMS5200 (Multicontroller) - Operating
condition 2
Measuring range and scale interval value for VMS5200 (Multicontroller) - Operating condition 3
Min.
Max.
Scale value (d)
Remarks
Length
100 mm
4.0"
5,500 mm
216.0"
10 mm
0.4"
Longest dimension of the measuring
object
Width
50 mm
2.0"
1,600 mm
63.0"
5 mm
0.2"
Dimension of the measuring object
orthogonal to the longest dimension
Height
50 mm
2.0"
1,100 mm
43.0"
5 mm
0.2"
Maximum height of the measuring
object relative to the transport belt
surface
Tab. 3: Measuring range and scale interval value for VMS5200 (Multicontroller) - Operating
condition 3