ORIGINAL OPERATING INSTRUCTIONS| VMS4200/5200 (Multicontroller)
• The 2D LiDAR sensors are mounted above the conveying equipment using the
mounting kit included in the scope of delivery.
• The mounting kit has a modular design and is preconfigured accordingly upon delivery.
• It consists of a width-adjustable telescopic tube with pre-mounted and pre-aligned
mounting plates to hold the 2D LiDAR sensors.
• The telescopic tube is attached to the customer’s frame via a pre-mounted attachment
mechanism, consisting of a mounting plate and a spring plate.
▸
Assemble the profiles of the telescopic tube.
▸
Mount the telescopic rod on the frame.
Fasten the 2D LiDAR sensor to the mounting plate.
NOTE! Adjustment after mounting is not required. The 2D LiDAR sensors have been
correctly pre-aligned at the factory by adjusting the orientation of the mounting plates
on the telescopic rod.
If an alternative attachment method is used (e.g., mounting the 2D LiDAR sensors on
a hollow shaft), adjustment will be required.
4.1.2 Assembling the profiles of the telescopic tube
Fig. 55: Assembling profiles of the telescopic tube
Legend
1 Main tube
2 Right and left telescopic tube
▸
Slide the right and left telescopic tubes into the main tube and fasten them with
screws.
▸
Adjust the tube to the desired width with the help of the markings.
Fig. 56: Markings on the telescopic tube
Mounting kit
Installation steps
Mounting