4 Mounting
All transport, assembly, mounting, and electrical installation work must only be carried out
by qualified persons.
• Qualified persons have the specialist training, skills, and experience, as well as
knowledge of the relevant regulations and standards, to be able to perform work
assigned to them and to identify and avoid any potential dangers independently.
• Electricians have the professional training, skills and experience, and knowledge of
the relevant standards and provisions to work on electrical systems and to detect
and avoid any potential dangers independently.
4.1 Mounting 2D LiDAR sensors
4.1.1 Overview
Fig. 54: Mounting the 2D LiDAR sensors
Legend
1 Telescopic rod with adjuster via defined wells
2 Components of the attachment mechanism for mounting the modular
bracket on the frame
• Mounting plate
• Spring plate
3 Mounting plates for mounting the LMS4x21 2D LiDAR sensors