e4595e11
29
Fire & Security Products
Siemens Building Technologies Group
05.2003
Mains
CT1142
(additional operating facilities)
Details see page 42
Basic equipment
Option
B3Q321
B2F020
AX12..
I-Bus
FBF FSK HM
E3L030
1..2
E3G070
Z3B171
1........7
CI1142
E3G...
E3L...
E3M...
B3R051
C-Bus
250VAC 10A
24V
E3C011
24V
5V
24V
Akkus
RT
24V
for details
see page 47
Fire control
installation
VdS peripheral
equipment
AlgoPilot
B3Q...
1
2
E3I020
RS232
RT = Remote transmission
K3I090
Pager
–> see page 86
or
internal or
external printer
Printer
> see page 82
LON synoptic converter
LON I/O card
Floor indicator terminal
–> see page 72ff
LON-Bus
K3I050
B3Q580/
B3Q59x
E3I040
K3I110
Modules H38G320
Control and operation
B3Q... Control terminal AlgoPilot all variants of the AlgoPilot see page 42
H26T... Plexiglass door to AlgoPilot B3Q... option see page 42
Z5B... Inscription set according to language see page 45, 46
E3G070 546661 Control module ’universal’ for alarm devices and control outputs
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Line modules according to detector series for details referring line modules see page 59
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
LON module for details referring floor indicator terminal see page 72
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Control modules if more than 7 programmable control outputs are required
for details referring control modules see page 66
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Interfaces as far as the space available allows installation
E3H020 546658 Gateway ’CERLOOP’ double Europe card (requires 2 module spaces)
E3I020 460239 RS232 module for connection of printer B2Q191 or non-Cerberus printer
K3I090 510820 Pager interface for connection of paging system/pager and internal/external printer
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Power supply for calculation of the emergency power operating period see page 91
B2F020 470588 Converter 115/230V
AC>29.6VDC 6A
E3C011 505479 Battery charging unit
AX1201 225487 Battery 12V/27Ah
AX1210 475570 Battery 12V/15Ah
Z3I450 484273 Mains socket ’CH’
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Cabinet/Accessories
H38G320 484943 Cabinet set ’door with cutout’ for details referring cabinets see page 53
H23B010 476210 Cover essential or H23B040 or B3Q321 or B3R051
H23B040 484590 Information module brief operating instructions instead of H23B010
B3Q321 460213 Fire department control terminal ’CH’ only CH
B3R051 490513 Parallel indicator terminal ”2x24 indicators” option
Z3I470 484341 Cable set for H38... essential
Z3I380 475567 I-Bus flat cable + supply cable ”long” required for connection from level to level
Z1K030 484231 Terminal block with p.c.b. chassis for CI11.. required per module (E3H020, E3L030 2 of each)
Z3B171 484383 Relay module 1 x 250V
AC/10A intermediate relay for fire control installations (max. 16)
Pre-configured cabinet
CI1142-NL 546988 Control unit in H38 housing pre-configured for ’NL’ requirements