5 System parameters
MICROMASTER 430 Operating Instructions
6SE6400-5AC00-0BP0
67
ParNr ParText Default Level DS QC
P1323[3] Programmable V/f volt. coord. 2 0.0 3 CUT N
P1324[3] Programmable V/f freq. coord. 3 0.00 3 CT N
P1325[3] Programmable V/f volt. coord. 3 0.0 3 CUT N
P1330[3] CI: Voltage setpoint 0:0 3 T N
P1333[3] Start frequency for FCC 10.0 3 CUT N
r1337 CO: V/f slip frequency - 3 - -
P1335[3] Slip compensation 0.0 3 CUT N
P1336[3] Slip limit 250 3 CUT N
P1338[3] Resonance damping gain V/f 0.00 3 CUT N
P1340[3] Imax controller prop. gain 0.000 3 CUT N
r1343 CO: Imax controller freq. output - 3 - -
P1341[3] Imax controller integral time 0.300 3 CUT N
r1344 CO: Imax controller volt. output - 3 - -
P1345[3] Imax controller prop. gain 0.250 3 CUT N
P1346[3] Imax controller integral time 0.300 3 CUT N
P1350[3] Voltage soft start 0 3 CUT N
Communication (P0004 = 20)
ParNr ParText Default Level DS QC
P0918 CB address 3 2 CT N
P0927 Parameter changeable via 15 3 CUT N
r0965 Profibus profile - 3 - -
r0967 Control word 1 - 3 - -
r0968 Status word 1 - 3 - -
r0964[5] Firmware version data - 3 - -
P0971 Transfer data from RAM to EEPROM 0 3 CUT N
P2000[3] Reference frequency 50.00 2 CT N
P2001[3] Reference voltage 1000 3 CT N
P2002[3] Reference current 0.10 3 CT N
P2003[3] Reference torque 0.75 3 CT N
r2004[3] Reference power - 3 - -
P2009[2] USS normalization 0 3 CT N
P2010[2] USS baudrate 6 3 CUT N
P2011[2] USS address 0 3 CUT N
P2012[2] USS PZD length 2 3 CUT N
P2013[2] USS PKW length 127 3 CUT N
P2014[2] USS telegram off time 0 3 CT N
r2015[8] CO: PZD from BOP link (USS) - 3 - -
P2016[8] CI: PZD to BOP link (USS) 52:0 3 CT N
r2018[8] CO: PZD from COM link (USS) - 3 - -
r2024[2] USS error-free telegrams - 3 - -
P2019[8] CI: PZD to COM link (USS) 52:0 3 CT N
r2025[2] USS rejected telegrams - 3 - -
r2026[2] USS character frame error - 3 - -
r2027[2] USS overrun error - 3 - -
www.eltra-trade.com
+421 552 601 099
info@eltra-trade.com

Table of Contents

Other manuals for Siemens MICROMASTER 430

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens MICROMASTER 430 and is the answer not in the manual?

Siemens MICROMASTER 430 Specifications

General IconGeneral
Power Range7.5 kW to 250 kW
Voltage Range380V to 480V
Frequency Range0 Hz to 650 Hz
Protection ClassIP20
Input Frequency47 Hz to 63 Hz
Digital Inputs6
Cooling MethodForced-air cooling
CommunicationUSS
Protection FeaturesOvervoltage, undervoltage, overcurrent, short-circuit, ground fault, overtemperature
Analog Inputs2
Digital Outputs3
Analog Outputs2
Ambient Temperature-10°C to +50°C
Control TypeSensorless vector control