EasyManuals Logo

Siemens SIMATIC IPC MD-34A User Manual

Siemens SIMATIC IPC MD-34A
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #76 background imageLoading...
Page #76 background image
Firmware/BIOS description
7.2 Configure firmware
MD-34A
76 Operating Instructions, 08/2023, A5E52427535-AA
Firmware setting Value Setting in deliv-
ery state
Meaning
TPM Availability
1
Available
x
The TPM (Trusted Platform Module) is
Available or Hidden in the operating
system.
Note: When it is set to Hidden mode, do
not expose TPM to 0.
Hidden
Clear TPM
Choose to remove all TPM context asso-
ciated with a specific owner.
Supervisor Pass-
word
Installed
It displays "Installed" here if Supervisor
Password is set.
Not Installed
x
User Password
Installed
You can set User Password after the
Supervisor Password is set. It displays
"Installed" here if User Password is set.
Not Installed
x
Set Supervisor
Password
Install or change the password.
The length of the password must be
greater than 1 character.
Set User Password
Install or change the password.
It's available for configuration only after
Supervisor Password is configured. The
length of the Password must be greater
than 1 character.
TLS Certificate
Manager
Maintain certificate files for TLS pro-
cessing. You can choose to import or
delete Certificate.
1
: Only visible with device configuration with Trusted Platform Module (TPM).
7.2.4 "Boot" tab
Boot behavior of the device, bootable device components (boot media) and boot order.
Calling "Boot" tab
Select: "Setup Utility (Page 71)" > "Boot".
Firmware setting Value Setting in deliv-
ery state
Meaning
Quick Boot
Enabled
x
Feature in BIOS that reduces computer
boot time.
Disabled
Quiet Boot
Enabled
x
Feature in BIOS that makes computer
start up faster and without usual error
messages on BIOS display.
Disabled
Network Stack
Enabled
x
Enable or disable the Network as a boot
device.
Disabled
PXE Boot capabil-
ity
1
Disabled
Enable Pre-Boot Execution Environment.
UEFI: IPv4
HTTP: IPv4
HTTP and PXE:
IPv4

Table of Contents

Other manuals for Siemens SIMATIC IPC MD-34A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC MD-34A and is the answer not in the manual?

Siemens SIMATIC IPC MD-34A Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC MD-34A
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals