HTTPS Server
Enable or disable HTTP access to the WBM.
HTTPS Port
Specify the port for HTTPS access to the WBM.
HTTP Services
Specify how the WBM is accessed:
HTTPS
Access to the WBM is only possible with HTTPS.
HTTP/HTTPS
Access to the WBM is only possible with HTTP and HTTPS.
Redirect HTTP to HTTPS
Access via HTTP is automatically diverted to HTTPS.
Min. TLS version
Specify which minimum TLS version is used.
Default Login Page
Specify the login page with which the WBM starts by default.
Firewall
Logging into the WBM page for user-specific firewall.
Configuration
Logging into the WBM.
SMTP Client
Enable or disable the SMTP client. You can configure other settings in "System > SMTP
Client".
Syslog Client
Enable or disable the Syslog client. You can configure other settings in "System > Syslog
Client".
DCP Server
Specify whether or not the device can be accessed with DCP (Discovery and Configuration
Protocol):
"-" (disabled)
DCP is disabled. Device parameters can neither be read nor modified.
Read/Write
With DCP, device parameters can be both read and modified.
Read Only
With DCP, device parameters can be read but cannot be modified.
Configuring with Web Based Management
4.5 "System" menu
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08 115

Table of Contents

Other manuals for Siemens SIMATIC NET SCALANCE S615

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC NET SCALANCE S615 and is the answer not in the manual?

Siemens SIMATIC NET SCALANCE S615 Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC NET SCALANCE S615
CategoryNetwork Router
LanguageEnglish

Related product manuals