Last Synchronization Mechanism
Shows how the last time synchronization was performed.
Not set
The time was not set.
Manual
Manual time setting
SNTP
Automatic time-of-day synchronization with SNTP
NTP
Automatic time-of-day synchronization with NTP
SIMATIC
Automatic time-of-day synchronization using the SIMATIC time frame
Daylight Saving Time
Shows whether the daylight saving time changeover is active.
active (offset +1 h)
The system time was changed to daylight saving time; in other words, an hour was
added. You can see the current system time at the top right in the selection area of the
WBM.
The set time continues to be displayed in the "System Time" box.
inactive (offset +0 h)
The current system time is not changed.
Procedure
1. Enable the "Time Manually" option.
2. Click in the "System Time" input box.
3. In the "System Time" input box, enter the date and time in the format "MM/DD/YYYY
HH:MM:SS".
4. Click the "Set Values" button.
The date and time are adopted and "Manual" is entered in "Last Synchronization
Mechanism" box.
Configuring with Web Based Management
4.5 "System" menu
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08 157