"Rule set" area
Name
Define a unique name for the rule set. If you click the "Create" button, a new row with a
unique number is created.
The table contains the following columns:
Select
Select the check box in the row to be deleted.
No.
Shows the unique number of the entry.
Name
Name of the rule set. The name can be changed if required.
Comment
Comment that describes the rule set in more detail.
Timeout [min]
Access is time-limited. Specify the duration of the access. If needed, the user can extend the
access time via the "Reset Timeout" button on the "User Specific Firewall" page.
"Rule Set Assignment" area
Type
Specify which rule set will be assigned to whom. The display of the following table depends
on the selection for "Type".
User Account
The rule set is activated through a user account.
Digital Input
The rule set is executed by controlling the digital input. The prerequisite for this is that the
entry "Digital Input" is activated for the "Firewall" event under "System > Events >
Configuration".
The "User Account" table contains the following columns:
User Account
Only users with the remote access "only" or "additional" are displayed.
Role
Shows the role of the user.
Rule set
Define the rule set that is valid for this user.
Combined
Combines the user login with an event, e.g. the "Digital Input" event. To log in to the WBM
page for the user-specific firewall, voltage must be present at the digital input and user login
must be successful.
Remaining Time
When this user is logged on, the remaining time for access is displayed.
Force Deactivate
A user with administrator rights can log off the active user with this button.