Description
IP Version
The version of the IP protocol.
Rule set
Select the required rule set. Only the IP rules that are assigned to this rule set will then be
displayed in the table, provided that "Show all" is disabled.
Show all
When enabled, all available IP rules are displayed. With the "Assign" setting, you assign an
IP rule to the selected rule set.
The table contains the following columns:
Select
Activate the check box in the row to be deleted.
Protocol
Shows the version of the IP protocol.
Action
Select how incoming IP packets are handled:
"Accept" - The data packets can pass through.
"Reject" – The data packets are rejected, and the sender receives a corresponding
message.
"Drop" – The data packets are discarded without any notification to the sender.
From / To
Specify the communications direction of the IP rule.
VLANx: VLANs with configured subnet
Device: Device
ppp0 or usb0 (only with M876-4): WAN interface
SINEMA RC: Connection to SINEMA RC Server
IPsec: Either all IPsec VPN connections (all) or a specific IPsec VPN connection
Configuring with Web Based Management
4.9 "Security" menu
SCALANCE S615 Web Based Management