Configuring with Web Based Management 
  4.4 "System" menu 
SCALANCE SC-600 Web Based Management (WBM) 
Configuration Manual, 10/2021, C79000-G8976-C475-03 
121 
•  Min. TLS version 
Specify the minimum TLS version to be used. 
•  Default Login Page 
Specify the login page with which the WBM starts by default. 
–  Firewall 
Logging into the WBM page for dynamic firewall.  
–  Configuration 
Logging into the WBM. 
•  SMTP Client 
Enable or disable the SMTP client. You can configure other settings in "System > 
SMTP Client". 
•  Syslog Client 
Enable or disable the Syslog client. You can configure other settings in "System > 
Syslog Client". 
•  DCP Server 
Specify whether the device can be accessed with DCP (Discovery and Configuration 
Protocol):  
–  "-" (disabled) 
DCP is disabled. Device parameters can neither be read nor modified. 
–  Read/Write 
With DCP, device parameters can be both read and modified. 
–  Read Only 
With DCP, device parameters can be read but cannot be modified. 
•  Time 
Select the setting from the drop-down list. The following settings are possible:  
–  Manual 
The system time is set manually. You can configure other settings in "System > 
System Time > Manual Setting". 
–  SIMATIC Time 
The system time is set via a SIMATIC time source. You can configure other 
settings in "System > System Time > SIMATIC Time Client". 
–  SNTP Client 
The system time is set via an SNTP server. You can configure other settings in 
"System > System Time > SNTP Client". 
–  NTP Client 
The system time is set via an NTP server. You can configure other settings in 
"System > System Time > NTP Client".