Configuring with Web Based Management
4.4 "System" menu
SCALANCE SC-600 Web Based Management (WBM)
122 Configuration Manual, 10/2021, C79000-G8976-C475-03
• SNMP
Select the protocol from the drop-down list. The following settings are possible:
– "-" (SNMP disabled)
Access to device parameters via SNMP is not possible.
– SNMPv1/v2c/v3
Access to device parameters is possible with SNMP versions 1, 2c or 3. You can
configure other settings in "System > SNMP > General".
– SNMPv3
Access to device parameters is possible only with SNMP version 3. You can
configure other settings in "System > SNMP > General".
• SNMPv1/v2 Read Only
Enable or disable write access to SNMP variables with SNMPv1/v2c.
• SNMPv1 Traps
Enable or disable the sending of SNMPv1 traps (alarm frames). You can configure
other settings in "System > SNMP > Traps".
• SINEMA Configuration Interface
If the SINEMA configuration interface is enabled, you can download configurations to
the device using STEP 7 Basic / Professional.
• DUID-Type
Specify which DUID type will be used. The DUID types are defined in RFC 3315.
– DUID-LLT
DUID is based on the link-layer address of the interface and a time stamp.
– DUID-EN
DUID is assigned by the vendor (EN = enterprise number).
– DUID-LL
DUID is based on the link-layer address of the interface.
• Link-layer Address Plus Time (LLT)
The value is based on the link-layer address of the interface and a time stamp. The
value is regenerated each time the factory settings are restored.
• Vendor Enterprise Number (EN)
The value is based on the enterprise number specific to the vendor. The value is
regenerated each time the factory settings are restored.