Programming via XML interface
10.3 XML commands
SIMATIC RF600
Configuration Manual, 11/2018, C79000-G8976-C386-07
181
<sourceName> value_sourceName </sourceName>
<duration> value_duration </duration> // opt
<unit> value_unit </unit> // opt
// opt → Optional: Line can be omitted.
<resultCode> 0 </resultCode>
<tagID> value_tagID </tagID>
<tagPC> value_tagPC </tagPC> // opt
<utcTime> value_utcTime </utcTime> // opt
<antennaName> value_antennaName </antennaName> // opt
<rSSI> value_rSSI </rSSI> // opt
<channel> value_channel </channel> // opt
<power> value_power </power> // opt
<polarization> value_polarization </polarization> // opt
<inventoried> value_inventoried </inventoried> // opt
<filterDataAvailable> value_filterDataAvailable
</filterDataAvailable> // opt
// opt → Optional: Line can be omitted.
The error codes for negative replies ("resultCode" ≠ 0) are described in the section "Negative
XML replies (Page 213)".