Service and maintenance
13.2 Error messages
SIMATIC RF600
256 Configuration Manual, 11/2018, C79000-G8976-C386-07
AutoId
status
XML/
LED
(hex)
OPC UA
status
AutoId
text
Error description
-- 0xCB OpcUa_
BadOutOf
Range /
OpcUa_
Bad
Configura-
tion
Error
-- No or bad configuration data/parameters were trans-
ferred.
Possible cause:
You are accessing a read point that is not configured.
-- 0xE1 BadInvalid
Argument
-- A parameter is missing.
-- 0xE2 BadInvalid
Argument
-- The parameter has an invalid format.
-- 0xE3 BadInvalid
Argument
-- The parameter type is invalid.
-- 0xE4 BadInvalid
Argument
-- Unknown parameter.
--
0xE5
Bad
--
The command or the frame has an invalid format.
Reading out error messages using the WBM
All the diagnostics messages of the reader are entered in the "Log" if a check mark was set
for "ERRORS" in the WBM configuration in "Settings - General". The log helps SIEMENS
specialists to analyze errors. You will find further information on the "Log" in the section "The
"Diagnostics - Log" menu item (Page 91)".