EasyManua.ls Logo

Siemens SIMATIC S5-95F - C.1.2 Supplementary Operations

Siemens SIMATIC S5-95F
579 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
S5-95F Operations List
C.1.2 Supplementary Operations
Oper-
ation
(STL)
Permisible
Operands
1 RLO depend.
2 RLO affected
3 RLO reloaded
123
Typical
Execution Time
in µs
On- Ext.
board I/O
Function
A= Formal operand
I/Q
F
T0 ... 63
T64 ... 127
C
NYN
65
65
480
85
65
AND operation: scan formal operand for "1".
(Data type: BI)
AN= Formal
operand
I/Q
F
T0 ... 63
T64 ... 127
C
NYN
65
65
480
85
65
AND operation: scan formal operand for "0".
(Data type: BI)
O= Formal
operand
I/Q
F,
T0 ... 63
T64 ... 127
C
NYN
65
65
480
85
65
OR operation: scan formal operand for "1".
(Data type: BI)
ON= Formal
operand
I/Q
F
T0 ... 63
T64 ... 127
C
NYN
65
65
480
85
65
OR operation: scan formal operand for "0".
(Data type: BI)
AW N N N 16 Combine contents of ACCU 2 and ACCU 1 through logic
AND (word operation).
Result is stored in ACCU 1. CC 1 / CC 0 are affected.
OW N N N 15 Combine contents of ACCU 2 and ACCU 1 through logic
OR (word operation).
Result is stored in ACCU 1. CC 1 / CC 0 are affected.
XOW N N N 16 Combine contents of ACCU 2 and ACCU 1 through logic
EXCLUSIVE OR (word operation).
Result is stored in ACCU 1. CC 1 / CC 0 are affected.
Boolean Logic Operations
for organization blocks (OB)
for program blocks (PB)
for function blocks (FB)
for sequence blocks (SB)
EWA 4NEB 812 6210-02
C-7

Table of Contents

Related product manuals