S7-300 Automation System Module data
Manual, 08/2006, A5E00105505-04
xv
Table 5-35 Representation of analog values in the ±10 V output range.................................................... 5-19
Table 5-36 Representation of analog values in the 0 V to 10 V and 1 V to 5 V output ranges .................
5-19
Table 5-37 Representation of analog values in the ±20 mA output range ................................................
5-20
Table 5-38 Representation of analog values in the 0 mA to 20 mA and 4 mA to 20 mA output ranges ...
5-20
Table 5-39 Dependencies of the analog IO values on the CPU's operating State and on the L+
supply voltage ..........................................................................................................................
5-24
Table 5-40 Reaction of analog input modules as a function of the actual analog value within the
range of values ........................................................................................................................
5-25
Table 5-41 Reaction of analog output modules as a function of the actual analog value within the
range of values ........................................................................................................................
5-25
Table 5-42 Diagnostic messages of analog input modules .......................................................................
5-33
Table 5-43 Diagnostics messages of analog output modules ...................................................................
5-33
Table 5-44 Diagnostics messages of analog input modules, causes of error and troubleshooting...........
5-34
Table 5-45 Diagnostics messages of analog output modules, causes of error and troubleshooting ........
5-34
Table 6-1 Analog input modules: Overview of properties ..........................................................................
6-3
Table 6-2 Analog input modules: Overview of properties (continued) .......................................................
6-4
Table 6-3 Analog output modules: Overview of properties ........................................................................
6-6
Table 6-4 Analog IO modules: Overview of properties ..............................................................................
6-7
Table 6-5 Measuring methods and ranges ..............................................................................................
6-13
Table 6-6 Overview of parameters of SM 331; AI 8 x 16 Bit....................................................................
6-13
Table 6-7 Assignment of SM 331; AI 8 x 16 Bit channels to channel groups ..........................................
6-14
Table 6-8 Minimum high and low limits of SM 331; AI 8 x 16 Bit.............................................................
6-16
Table 6-9 Measuring methods and ranges ..............................................................................................
6-22
Table 6-10 Assignment of SM 331; AI 8 x 16 Bit channels to channel groups ..........................................
6-22
Table 6-11 Overview of parameters of SM 331; AI 8 x 16 Bit....................................................................
6-23
Table 6-12 Cycle times in 8-channel mode................................................................................................
6-25
Table 6-13 Measuring methods and ranges ..............................................................................................
6-33
Table 6-14 Assignment of SM 331; AI 8 x 14 bits High Speed channels to channel groups.....................
6-33
Table 6-15 Overview of parameters for SM 331; AI 8 x 14 Bit High Speed...............................................
6-34
Table 6-16 Conditions of isochronous mode:.............................................................................................
6-35
Table 6-17 Parameters of SM 331; AI 8 x 13 Bit .......................................................................................
6-47
Table 6-18 Measuring methods and ranges ..............................................................................................
6-57
Table 6-19 Assignment of SM 331; AI 8x12 bit channels to channel groups ............................................
6-58
Table 6-20 Overview of parameters for SM 331; AI 8 x 12 bit...................................................................
6-59
Table 6-21 Measuring methods and ranges ..............................................................................................
6-69
Table 6-22 Overview of parameters of SM 331; AI 2 x 12 Bit....................................................................
6-71
Table 6-23 Measuring methods and ranges ..............................................................................................
6-79

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)