Advanced commissioning
7.2 Inverter control
Digital outputs
Changing the function of a digital output
igital output with a binector output of
Binector outputs are marked with "BO" in the parameter
list of the List Manual.
Table 7- 2 Binector outputs of the inverter (selection)
Deactivating digital output
f_actual >= p1082 (f_max)
Drive ready for operation
Alarm: Motor current/torque limit
Setpoint/actual value discrepancy
f_actual ≥ setpoint (f_setpoint)
A complete list of the binector outputs is provided in the List Manual.
Changing the function of a digital output - example
In order to output the fault message over the digital output
DO
1, you have to connect the DO 1 with the fault message:
You can invert the signal of the digital output using parameter p0748.
For more information, see the parameter list and the function block diagram 2241 of the List
Manual.
Converter with control units CU240D-2
Operating Instructions, 04/2015, FW V4.7.3, A5E34262100B AB
121