3.3 Motor series that are supported
3.3
Motor series that are supported
Supported motors
Table 3- 5 Motor series suitable for the inverter
SIMOTICS GP, SIMOTICS SD IEC motors
1LG6, 1LA7, 1LA9 and 1LE1 standard induction
motors
Multi-motor drive is permissible, i.e. multiple mo-
tors operated on one inverter. See also: Multi-
motor drive
(
http://support.automation.siemens.com/WW/view/
en/84049346).
SIMOTICS M main motors
1PH8 induction motors
SIMOTICS S 1FK7 encoderless permanent-field
synchronous motors
1FK7 synchronous motors
SIMOTICS 1FG1 encoderless geared synchro-
nous motors
1FG1 geared synchronous motors
Motors from other manufacturers
Standard induction motors
Operation with encoderless synchronous motor 1FK7 or 1FG1
The control dynamic that can be achieved using a synchronous motor corresponds to that of
an induction motor:
Power-up time from standstill to rated speed ≥ 1 s
Starting torque ≤ 2 × rated torque of the motor
This type of operation is intended for applications in which greater energy efficiency is
required than can be achieved with an induction motor.