9 OLL Overload level reached
• 1: motor has reached the parameterizable output over-
load level (p29080 in % of rated torque, default: 100%,
max: 300%)
• 0: motor has not reached the overload level
✓ ✓ ✓ ✓
10 WARNING1 Warning 1 condition reached
• 1: parameterizable warning 1 condition has been
reached.
• 0: warning 1 condition has not been reached.
✓ ✓ ✓ ✓
11 WARNING2 Warning 2 condition reached
• 1: parameterizable warning 2 condition has been
reached
• 0: warning 2 condition has not been reached.
See note below
✓ ✓ ✓ ✓
12 REFOK Referenced
• 1 = Referenced
• 0 = Not referenced
X ✓ X X
13 CM_STA Current control mode
• 1 = The second mode in five compound control modes
(PTI/S, IPos/S, PTI/T, IPos/T, S/T)
• 0 = The first mode in five compound control modes or
four basic modes (PTI, IPos, S, T)
✓ ✓ ✓ ✓
14 RDY_ON Ready for servo on
• 1: ready to servo on
• 0: drive is not ready for servo on (a fault occurs or the
main power supply is missing)
after the drive is in "S ON" state, the signal remains
at high level (1) unless the above abnormal cases happen.
✓ ✓ ✓ ✓
15 STO_EP STO active
• 1: the enable signal is missing, indicating that STO is
active.
• 0: the enable signal is available, indicating that STO is
inactive.
STO_EP is only a status signal for STO input termi-
nals but not a safe DO for the Safety Integrated function.
✓ ✓ ✓ ✓