Task navigation
SINAMICS V-ASSISTANT Online Help
114 Operating Manual, 04/2017, A5E36618042-003
4.4.3.2
Real-time auto tuning
Note
Under operating conditions that impose sudden disturbance torque during
acceleration/deceleration or on a machine that its ri
gidity is poor, auto tuning may not
function properly, either. In such cases, use one
-button auto tuning or manual tuning to
optimize the drive.
With real-time auto tuning, the servo drive can automatically estimate the ratio of load
moment of inertia and set the optimum control parameters.
Prerequisites for real-time auto tuning
The drive must be controlled by the host controller.
The machine actual load moment of inertia is different when the machine moves to the
different positions.
Make sure that the motor has multiple accelerations and decelerations. Step command is
recommended.
Machine resonance frequency changes when the machine is running.
Implement the following steps to use the real-time auto tuning function:
1.
Select the dynamic factor in the following area:
For more information about sel
ecting the dynamic factor, see the SINAMICS V90,
SIMOTICS S-1FL6 Operating Instructions.
2.
Click the following button to configure the parameters for the real
-time auto tuning func-
tion.