78 Operating Manual, 04/2017, A5E36618042-003
Seven signals in total can be linked with either analog output. For more information, see
Section "Analog outputs (AOs) (Page 106)".
By default, analog output 1 and analog output 2 are linked with actual speed and actual
torque respectively. You can freely select the target signal in the drop-down list to link with
analog outputs.
4.3.7
Configuring referencing
Referencing is only available in IPos and EPOS control modes.
Two sub-functions are available:
Setting referencing (Page 78)
Setting software position limit (Page 84)
4.3.7.1
Setting referencing
Setting referencing is
only
available in online mode.
Setting referencing (in IPos control mode)
Incremental encoder
If the motor is equipped with an incremental encoder, five referencing modes in total are
available:
Parame-
ter
Value
Referencing mode
Illustration
p29240 0 Setting the refer-
ence point via
digital input (signal
REF)