77
Assigning digital outputs for V90 PTI
A total of 14 signals can be freely linked to digital outputs. For more information, see
Section "DOs (Page 102)".
Click the cells with white background in the table. Select
"Assign"
to link the digital input
with the corresponding signal. Then the current cell displays grey.
Note
DO signal inverse
The logics of digital output signals DO1 to DO6 can be inversed. You can inverse the
logics of DO1 to DO6 by setting the bi
t 0 to bit 5 of parameter p0748.
4.3.6.3
Assigning analog outputs (V90 PTI only)
You can assign analog outputs on the panel below: