Analog outputs (AOs)
Two parameters, p29350 (selects signal sources for AO1) and p29351 (selects signal
sources for AO2), are used to select the source of analog output:
Parame-
ter
Value
Source
Value
Source
p29350 0 (de-
fault)
Actual speed (reference
p29060)
7
Pulse input frequency (reference 100
k)
1 Actual torque (reference 3 ×
r0333)
8 Pulse input frequency (reference
1000 k)
2 Speed setpoint (reference
p29060)
9 Remaining number of pulses (refer-
ence 1 k)
3 Torque setpoint (reference 3 ×
r0333)
10 Remaining number of pulses (refer-
ence 10 k)
4 DC bus voltage (reference
1000 V)
11 Remaining number of pulses (refer-
ence 100 k)
5 Pulse input frequency (refer-
ence 1 k)
12 Remaining number of pulses (refer-
ence 1000 k)
6 Pulse input frequency (refer-
ence 10 k)
p29351 0 Actual speed (reference
p29060)
7
Pulse input frequency (reference 100
k)
1 (de-
fault)
Actual torque (reference 3 ×
r0333)
8 Pulse input frequency (reference
1000 k)
2 Speed setpoint (reference
p29060)
9 Remaining number of pulses (refer-
ence 1 k)
3 Torque setpoint (reference 3 ×
r0333)
10 Remaining number of pulses (refer-
ence 10 k)
4 DC bus voltage (reference
1000 V)
11 Remaining number of pulses (refer-
ence 100 k)
5 Pulse input frequency (refer-
ence 1 k)
12 Remaining number of pulses (refer-
ence 1000 k)
6 Pulse input frequency (refer-
ence 10 k)