4.4.3.3
Manual tuning
When the auto tuning function cannot reach the expected tuning results, you can disable the
auto tuning function by setting the parameter p29021 and manually perform tuning:
p29021=5: auto tuning function is disabled and all control parameters are reset to tuning
default values.
p29021=0: auto tuning function is disabled without changing control parameters.
Parameter settings
You can set the parameters on the following panel:
Click to reset the following parameters to their tuning defaults. The tuning
default values of the parameters are different when you use the different drives and motors.
The function of the button is not drive default so the tuning default values of the control
parameters are different with their factory settings.
p1414
p1415
p1656
p1658
p1659
p2533
p29110[0]