Description
When number of setpoint pulses per motor revolution (p29011) is 0, configure electronic
gear ratio by setting numerator (p29012) and denominator (p29013).
When number of setpoint pulses per motor revolution is not 0, enter the number of set-
point pulses per motor revolution here.
Calculate the electronic gear ratio according to different mechanical structures.
Totally, five mechanical structures are available:
Ball screw
Disc table
Belt pulley
Rack and pinion
Roll feed
For more information, see Section "Mechanical structure (Page 54)".
Enter the pitch value and gear ratio, select a display unit and click
. Then the
electronic gear ratio can be calculated automatically.
4.3.1.2
Mechanical structure
Variables
Configure variables according to the selected mechanical structure:
Mechanical
structure
Graphical view
Variable setting
Variable
Range
Ball screw
P: Pitch value (mm) 0.0001 to
2147000000
N: Load revolutions
1 to 2147000000
M: Motor revolutions 1 to 2147000000
Disc table
N: Load revolutions
1 to 2147000000
M: Motor revolutions 1 to 2147000000
Belt pulley
D: Diameter (mm)
0.0001 to
2147000000
N: Load revolutions
1 to 2147000000
M: Motor revolutions 1 to 2147000000