120 Operating Manual, 04/2017, A5E36618042-003
Speed loop PI/P switching
Five switching modes in total are available for PI/P switching:
using torque setpoint
using an external digital input signal (G-CHANGE)
using speed setpoint
using acceleration setpoint
using pulse deviation
If you select either of the PI/P switching modes (except the second mode), you need to
set the conditional threshold as shown in the above screenshot.
Note
PI/P switching
This function is not
available in
T
mode and responds with a delay of several
milliseconds.
4.4.3.4
Low frequency vibration suppression
Low frequency vibration suppression is a position setpoint filter function. It can suppress the
vibration frequency within 0.5 Hz to 62.5 Hz.
This function is only available in IPos and EPOS control modes.
Parameter settings
To use the vibration suppression function, you need to configure the following parameters
accordingly:
Parameter
Value range
Default
value
Unit
Description
p29035 0 to 1 0 - Vibration suppression activation
= 0: disable
= 1: enable
p31581 0 to 1 0 - Vibration suppression filter type
= 0: rugged
= 1: sensitive
p31585
0.5 to 62.5
1
Hz
Vibration suppression filter frequency
p31586
0 to 0.99
0.03
-
Vibration suppression filter damping