Switching modes
The following two switching modes are only available for V90 PTI:
These two switching modes cannot be used at the same time. Once one mode is enabled,
the other one becomes disabled. The functions of auto-tuning and gain switching must be
disabled so that the function of PI/P switching can be available. When the gain switching
function is enabled, the PI/P switching function is disabled and the settings can not be
cleared.
Gain switching
Five gain switching modes in total are available:
Gain switching disabled
Gain switching using digital input signal (G-CHANGE)
Gain switching using position deviation
Gain switching using position setpoint frequency
Gain switching using actual speed
If you select either of the last three gain switching modes, you need to set the conditional
threshold.