Task navigation
SINAMICS V-ASSISTANT Online Help
Operating Manual, 04/2017, A5E36618042-003
149
02 hex:
Integer 8
03 hex:
Integer 16
04 hex:
Integer 32
05 hex:
Unsigned 8
06 hex:
Unsigned 16
07 hex:
Unsigned 32
08 hex:
Floating Point
0A hex:
Octet String
0D hex:
Time Difference
34 hex
: TimeOfDay without date indication
35 hex
: TimeDifference with date indication
36 hex
: TimeDifference without date indication
41 hex:
Byte
42 hex:
Word
00 hex ... EA hex
The table below formats the response when the drive has executed the change request.
Reference (identical to a change request)
02 hex (change request successful)
(ID of drive objects, at V90
always = 2)
(identical to a change
2
The table below formats the response when the drive was not able to completely execute the
change request.
(identical to a change request)
(Drive was not able to completely
execute the write request)
0
(ID of drive objects, at V90
always = 2)
(identical to a change
2
40 hex: Zero (change request for this data
block executed)
44 hex: Error (change request for this data
00 hex
01 hex or 02 hex
4
Only for "Error" -
You can find the error values in the table at the end of this section.
6
Only for "Error" -
Error value 2 is either zero, or it contains the number of the first index where the error oc-
8