Operating Manual, 04/2017, A5E36618042-003
49
The PZD in green indicates that it has a bit definition. You can read the binary value of each
bit from the table.
Supported telegrams
SINAMICS V90 PN supports standard telegrams and Siemens telegrams for speed control
mode. You can select the desired telegram with parameter p0922. See the following table for
details.
From the perspective of the drive unit, the received process data represents the receive
words and the process data to be sent to the send words.
Telegram
Maximum number of PZD
Description
Receive word
Send word
Standard telegram 1
2
2
p0922 = 1
Standard telegram 2
4
4
p0922 = 2
Standard telegram 3
5
9
p0922 = 3
Standard telegram 5
9
9
p0922 = 5
Standard telegram 7
2
2
p0922 = 7
Standard telegram 9
10
5
p0922 = 9
Siemens telegram 102
6
10
p0922 = 102
Siemens telegram 105
10
10
p0922 = 105
Standard telegram 110
12
7
p0922 = 110
Standard telegram 111 12 12 p0922 = 111
One PZD = one word
Standard telegram 5 and Siemens telegram 105 can only be used when the V90 PN connects to the SIMATICS S7
-1500