Page #89 background image
5 Configuring 11.92
5.8 FB 128 Transfer
Data transfers always involve the entire width of the magazine table. This includes:
DBZW+1
DBZW+2
DBZW+3
ID number
Duplo number
User DBs (1...7)
Reference DBs (1...9)
Block data
Lib. No. : E88530-B5528-A
FBs to be loaded : FB 128, FB 131, FB 132, FB 135, FB 152
DBs to be loaded : -
Type of FB call : Conditional, unconditional
DBs to be input : -
Error messages : %4: During the transfer of D No., which is initiated internally,
the subroutine FB 135 "Provide D No." has reported an
error.
%5: Inadmissible status of internal coordination signals
01: Source magazine not available
02: Source location not available
03: Target magazine not available
04: Target location not available
05: Transfer to old location not possible -
transfer in reverse direction
06: Channel No. for "Provide D No." cannot be determined.
(No old location entered in the tool buffer.)
Warning: Data transfer has been carried out within the
magazine table.
07: Target location assigned
(target address DB status word (DBZW)+2/bit 15 set)
08: Error when assessing adjacent location
09: More than four multi-cycle data transfer functions are
simultaneously active.
10: Target and/or source location is disabled.
11: No loading memory defined.
12: Source or target is not a fictitious magazine
13: Error while accessing adapter data in P8 and P9 (out of
range with FB 62)
Caution: The tool was marked as "not released".
16: The function "Reserve/enable location" cannot be carried
out for transfer direction reasons from magazine location
to tool buffer and vice versa.
17: Automatic enable of location reservation is not possible
(transfer has however been executed correctly).
Note: "Multi-cycle mode"
Multi-cycle mode means that the processing of an initiated transfer function extends over
several PLC cycles. This is always necessary for loading the spindle (transfer of D No. into R
parameters), definition of P8 and P9 during transfer into a turret and in the case of unequal TO
areas in source and target (TO data transfer available soon).
5–28
© Siemens AG 1991 All Rights Reserved 6FC5 197-0AA40-1BP1
SINUMERIK 840/880 (PJ)

Table of Contents

Other manuals for Siemens SINUMERIK 840

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840 and is the answer not in the manual?

Siemens SINUMERIK 840 Specifications

General IconGeneral
Control TypeCNC
AxesUp to 31
DisplayTFT color display
PLCIntegrated
HMISINUMERIK Operate
Communication InterfacesEthernet, PROFIBUS, PROFINET
TypeCNC system
Programming LanguagesG-code
Max Number of Channels10
Operating Temperature0 to 45 °C
Relative HumidityUp to 95% (non-condensing)
Protection ClassIP54 (front panel)